Solar Panel Roof Load Calculator

Solar Panel Roof Load Calculator — quick estimate

Before anyone lifts a panel, the structural question: how much dead load will the array add, and can the roof take it? Estimate the kg/m² and total tonnage by mounting type — then have the structure actually checked.

Your roof & system

250 kWp

Working bands: metal-sheet rail-mount ~15 kg/m², elevated RCC frame ~20 kg/m², ballasted RCC ~30 kg/m² (ballast included), over ~9.3 m²/kWp of array area.

Added dead load
Total added weight
Array area
Array area (sq.ft)
Weight per kWp
Governing check

Get a structural check with your solar proposal — free

Our team assesses roof adequacy as part of the site survey and designs the structure to IS 875 wind loads. Tell us your roof and we'll take it from here.

🔒 Your estimate is attached automatically. No spam — ever.

or reach us directly

Indicative dead-load bands only — not a structural verdict. Wind uplift (IS 875), point loads at supports and your slab's actual condition govern; a structural adequacy assessment settles it.

Questions engineers and CFOs ask

How much weight does rooftop solar add to my roof?

As a working band: rail-mounted arrays on metal-sheet roofs add roughly 12–15 kg/m² of array area, elevated frames on RCC roofs around 18–22 kg/m², and ballasted RCC systems 25–35 kg/m² because the concrete ballast blocks that hold them down are most of the weight. These are dead loads spread over the array footprint — point loads at feet and pedestals matter separately.

Can my RCC roof take solar panels?

A structurally sound RCC slab designed to Indian codes typically carries live loads far above what a solar array adds, so most healthy roofs are fine. The honest answer for YOUR roof, though, comes from a structural assessment — age, cracks, water tanks, existing services and cantilevers all matter, and a stamped structural adequacy certificate is exactly what a lender or insurer will ask to see.

What about wind load — isn't that bigger than the weight?

Often, yes. Uplift on an elevated array in a storm can exceed its dead weight, which is why structures are designed to IS 875 wind maps for your location and why ballasted systems need enough mass to stay put. Weight is the question everyone asks; anchorage against uplift is the one the structural design actually sweats over.

Metal-sheet roof — will the panels damage the sheeting?

Not when the array clamps to the standing seams or fixes into the purlins through proper interfaces with EPDM sealing. What damages sheet roofs is walking traffic during careless installation and cleaning, and drilling that misses purlins. Specify walkways, purlin-fixed rails and a cleaning access plan and a sheet roof carries solar for decades.

Need an exact BOQ, rate analysis or measurement sheet?

This is a quick engineering estimate. For tendering, billing or audit, our QS & estimation team prepares an item-wise BOQ, rate analysis and a verified measurement sheet to IS / CPWD norms — backed by 15+ years and ISO 9001:2015 quality processes.

ONE PARTNER. END TO END. You focus on your business — we handle the rest.
Quality Safety Commitment
Send your bill 10-minute assessment