Last reviewed · Reviewed for Fire NOC process, issuing department, state fire act Authority names, portals, fees and timelines change with state notifications; confirm the live position with the authority before relying on it.

Fire NOC for factories in Rajasthan — the process nobody expects

Here’s the fact that surprises most factory owners moving into Bhiwadi, Neemrana or the wider Alwar-Jaipur corridor: Rajasthan has no dedicated fire-safety act. Unlike Punjab, Haryana, Delhi or UP — all of which have a standalone Fire and Emergency Services Act — Rajasthan routes Fire NOC through Section 337 of the Rajasthan Municipalities Act, 2009, administered by the Department of Local Self Government, not a fire directorate.

This page covers what’s specific to Rajasthan. For the full NBC 2016 engineering — the two-stage process, document checklist, cost drivers, and the 10 reasons fire schemes get rejected — see the complete Fire NOC guide (written for Punjab/Haryana/UP, but the engineering content applies here too).

Who issues it, and under what law

Rajasthan
Issuing authorityDepartment of Local Self Government (LSG)
Governing lawRajasthan Municipalities Act, 2009, Section 337 (read with Section 225) — no dedicated fire act
Application routeSSO Rajasthan portal, or local Chief/Regional Fire Officer
LSG head officeJaipur (G-3, Rajmahal Residential Area, C-Scheme)
Industrial estate coordinationRIICO

Why this matters for a Bhiwadi or Neemrana project

If your fire consultant is used to working in Punjab or Haryana, the legal citation on your NOC will look unfamiliar — there’s no “Rajasthan Fire and Emergency Services Act” to reference, because it doesn’t exist. That’s not a gap in the process; it’s a genuinely different administrative structure. The NBC 2016 engineering requirement is identical — the same hydrant, sprinkler, tank and exit rules apply — but the approving authority is your local Municipal Corporation via the LSG Department, not a state fire service.

This is also a real point of confusion for factory owners who assume Bhiwadi and Neemrana follow Haryana’s rules because they sit so close to the Gurugram-Manesar belt. They don’t — Bhiwadi and Neemrana are in Alwar district, Rajasthan, under RIICO, JVVNL, RSPCB and the LSG Department, not HSIIDC, DHBVN, HSPCB or the Haryana Fire Act.

Where we work in Rajasthan

We deliver fire-NOC design and filing across Rajasthan’s RIICO estates: Bhiwadi, Neemrana (Japanese Zone), Khushkhera, Tapukara, Sitapura, Jaipur, and Kotputli-Behror — see the full Rajasthan zone list.

Get your fire scheme designed and filed

Secured Engineers Pvt. Ltd. is an MEPF and fire-protection EPC contractor extending our pan-India coverage into Rajasthan’s Alwar-Jaipur corridor. This guide is general information; confirm current rules with the Department of Local Self Government.

Frequently asked questions

Does Rajasthan have a dedicated Fire Act?

No. Rajasthan is one of the few major Indian states without a standalone fire-safety act or dedicated fire directorate. Fire NOC is instead granted under Section 337 (read with Section 225) of the Rajasthan Municipalities Act, 2009.

Which department issues the Fire NOC in Rajasthan?

The Department of Local Self Government (LSG), Government of Rajasthan, issues Fire NOC as a prerequisite for building-plan approval from the relevant Municipal Corporation — not a separate fire department.

How do I apply for a Fire NOC in Rajasthan?

Applications are filed through the SSO Rajasthan portal, or via the local Chief Fire Officer / Regional Fire Officer. The LSG Department's head office is in Jaipur.

Is the Fire NOC process different for Bhiwadi and Neemrana versus Jaipur?

The governing framework (Municipalities Act, 2009) is the same statewide. The practical difference is which municipal body processes the application — different for RIICO-administered industrial areas versus city-limits plots.

Does the absence of a dedicated fire act mean lower fire-safety standards?

No — NBC 2016 Part 4 still applies as the technical standard for what your building must install (hydrants, sprinklers, tanks, exits). What's different is the legal/administrative route to the NOC, not the engineering requirement.

Are there informal fire-safety rules referenced alongside the Municipalities Act?

Yes — non-statutory 'Fire Prevention and Fire Safety Rules' and building bylaws are referenced informally alongside the Act. We design to NBC 2016 and current LSG practice regardless of which document is cited.

Sources and standards

  • NBC 2016 Part 4 (2016) — National Building Code of India 2016, Part 4 — Fire and Life Safety. Bureau of Indian Standards. Publisher.Occupancy classification, fire-protection systems required by building type and height, static water storage, pumps, exits, refuge, compartmentation, stair pressurisation.
  • IS 15105 (2002 (reaffirmed)) — IS 15105 — Design and Installation of Fixed Automatic Sprinkler Fire Extinguishing Systems — Code of Practice. Bureau of Indian Standards. Publisher.Sprinkler hazard classification, design density, head spacing and coverage, water supplies.
  • IS 3844 (1989 (reaffirmed)) — IS 3844 — Code of Practice for Installation and Maintenance of Internal Fire Hydrants and Hose Reels on Premises. Bureau of Indian Standards. Publisher.Internal hydrants, landing valves and hose reels.
  • IS 2189 (2008) — IS 2189 — Selection, Installation and Maintenance of Automatic Fire Detection and Alarm System — Code of Practice. Bureau of Indian Standards. Publisher.Detector selection, zoning, installation and maintenance of fire alarm systems.
  • State Fire Service Acts and Rules — State Fire and Emergency Services Acts and Rules (state-specific). State governments. Fire NOC application, inspection, issue and renewal — the process and periodicity differ by state.

Standards are cited to support the technical statements on this page. Where a standard has been revised, the edition shown is the one verified at the time of review; the edition in force for a project is the one the authority applies.

Need help with Fire NOC for Factories in Rajasthan?

Tell us about your project — our engineers respond within one business day.

  • ★ 4.7 (230 Google reviews)
  • 535+ projects
  • ISO 9001:2015 Certified
  • Reply in 1 business day