Skip to content
Secured Engineers Pvt. Ltd. logo
Home
Company Insights Resources About Founder — Er. Ankur Kaplesh
Services Mechanical / HVACElectricalPlumbingFire ProtectionLow Voltage / ELVSolar EPCDesign & ApprovalsAMC / MaintenanceTurnkey EPCFire NOC AssistanceCEIG Liaison & EnergisationTesting & CommissioningIndustrial Audits
Industries Manufacturing & IndustrialHealthcare & HospitalsHospitality & HotelsWarehousing & LogisticsGovernment & DefenceEducation & InstitutionsData CentrePharmaceutical & CleanroomCold StorageTextile & ApparelAutomobile & Auto-ComponentsFood Processing & FMCGChemical & Process Industries
Free Tools ★ Architect & Design Resource Hub All 29 calculators Solar Savings Calculator Fire Water Tank Calculator Fire Pump Room Calculator AC Tonnage Calculator DG Set Sizing Calculator MEPF Cost Estimator
Projects Work With Us Get a Free Quote

Clean-agent and special-hazard fire suppression contractor — NOVEC 1230, FM-200, CO₂ and water mist

Clean-agent (NOVEC/FM-200), CO₂ and water-mist suppression for server rooms, panels, archives and special hazards where water would cause damage.

Enquire: Gas & Special-Hazard Suppression

Step 1 of 3

What do you need?
What kind of facility?
Roughly how big is the project?
Where should our engineer call you?

No forms to chase — an engineer calls you back. We never share your number.

In one paragraph

Gas & Special-Hazard Suppression by Secured Engineers Pvt. Ltd.

Secured Engineers Pvt. Ltd. — an ISO 9001:2015-certified MEPF and solar EPC contractor with offices in Ludhiana, Punjab and Noida (Delhi NCR) — provides Gas & Special-Hazard Suppression as part of its Fire Protection scope: Clean-agent (NOVEC/FM-200), CO₂ and water-mist suppression for server rooms, panels, archives and special hazards where water would cause damage. 535+ projects across 18+ Indian states.

Enquiries: +91 70099 87817 · sales@securedengineers.com · request a project proposal

Why it matters

What this system decides for your project

Some assets can't be protected with water. Clean-agent systems flood the risk and extinguish fire in seconds without harming electronics, records or people.

You need a quote for this if: Data centres, server/UPS rooms, electrical rooms and archives.

Scope

Scope of work

The agent is chosen for the risk — clean agents where electronics, records or people are present, CO₂ for unoccupied electrical or machinery enclosures, water mist where the hazard suits it — and the quantity is calculated from the protected volume and the design concentration the agent's listing requires. The design covers the cylinders and their location, the pipework and nozzle layout for discharge time and distribution, the detection that triggers release (usually cross-zoned) with its delay and abort arrangements, and the room's dampers and door closers. We supply and install the cylinders, valves, pipework, nozzles, detection and control panel.

How it is delivered — and what you receive

The protected room is integrity-tested to show it will hold the agent concentration for the required time — leaks around cable penetrations and ceiling voids are the usual failure — and the release sequence is tested electrically without discharge. Warning signage and the manual release are placed as the standard requires. The client receives the agent calculation, the integrity-test result, the release logic and the cylinder schedule for the AMC's weighing checks.

Sources and standards

  • NBC 2016 Part 4 (2016) — National Building Code of India 2016, Part 4 — Fire and Life Safety. Bureau of Indian Standards. Publisher.Occupancy classification, fire-protection systems required by building type and height, static water storage, pumps, exits, refuge, compartmentation, stair pressurisation.
  • IS 3844 (1989 (reaffirmed)) — IS 3844 — Code of Practice for Installation and Maintenance of Internal Fire Hydrants and Hose Reels on Premises. Bureau of Indian Standards. Publisher.Internal hydrants, landing valves and hose reels.
  • IS 15105 (2002 (reaffirmed)) — IS 15105 — Design and Installation of Fixed Automatic Sprinkler Fire Extinguishing Systems — Code of Practice. Bureau of Indian Standards. Publisher.Sprinkler hazard classification, design density, head spacing and coverage, water supplies.
  • IS 2189 (2008) — IS 2189 — Selection, Installation and Maintenance of Automatic Fire Detection and Alarm System — Code of Practice. Bureau of Indian Standards. Publisher.Detector selection, zoning, installation and maintenance of fire alarm systems.
  • State Fire Service Acts and Rules — State Fire and Emergency Services Acts and Rules (state-specific). State governments. Fire NOC application, inspection, issue and renewal — the process and periodicity differ by state.

Standards are cited to support the technical statements on this page. Where a standard has been revised, the edition shown is the one verified at the time of review; the edition in force for a project is the one the authority applies.

Before you ask us to quote: the Fire Protection buyer's guide lists what to have ready, what drives cost and timeline, and the approvals that usually apply.

Approved makes

Makes we specify for Gas & Special-Hazard Suppression

Tier-1 manufacturers whose equipment we design around and install. The specification names the make; the site is held to it.