Fire alarm system contractor — addressable and conventional detection to IS 2189

Addressable and conventional fire detection — smoke/heat detectors, MCPs, panels, sounders and integration with PA and building systems.

Enquire: Fire Detection & Alarm

Step 1 of 3

What do you need?
What kind of facility?
Roughly how big is the project?
Where should our engineer call you?

No forms to chase — an engineer calls you back. We never share your number.

In one paragraph

Fire Detection & Alarm by Secured Engineers Pvt. Ltd.

Secured Engineers Pvt. Ltd. — an ISO 9001:2015-certified MEPF and solar EPC contractor with offices in Ludhiana, Punjab and Noida (Delhi NCR) — provides Fire Detection & Alarm as part of its Fire Protection scope: Addressable and conventional fire detection — smoke/heat detectors, MCPs, panels, sounders and integration with PA and building systems. 535+ projects across 18+ Indian states.

Enquiries: +91 70099 87817 · sales@securedengineers.com · request a project proposal

Why it matters

What this system decides for your project

Early detection buys the minutes that save lives. Addressable systems pinpoint the exact location of a fire and integrate with evacuation and HVAC for a coordinated response.

You need a quote for this if: Any occupied building — mandatory life-safety and a Fire-NOC requirement.

Scope

Scope of work

Detection is designed zone by zone to IS 2189 — the detector type for the space (smoke, heat, multi-sensor, beam or aspirating where the ceiling height or the environment calls for it), spacing and placement, manual call points at exits, sounders and strobes for audibility and visibility, and the panel with its loops and cause-and-effect matrix. Addressable systems identify the device; conventional systems identify the zone. Integration covers the PA and voice evacuation, HVAC shutdown and damper release, lift homing, access-control release and the sprinkler flow switches. We supply and install the devices, cabling, panels and interfaces.

How it is delivered — and what you receive

Every device is tested individually and the cause-and-effect matrix is proven end to end — smoke at a detector must produce the right alarm, the right announcement, the right shutdowns and the right releases — which is the test the fire officer wants to see. Cable is fire-rated where the standard requires it and the loops are documented. The client receives the device schedule with addresses, the cause-and-effect matrix, the test records and the panel configuration.

Sources and standards

  • NBC 2016 Part 4 (2016) — National Building Code of India 2016, Part 4 — Fire and Life Safety. Bureau of Indian Standards. Publisher.Occupancy classification, fire-protection systems required by building type and height, static water storage, pumps, exits, refuge, compartmentation, stair pressurisation.
  • IS 3844 (1989 (reaffirmed)) — IS 3844 — Code of Practice for Installation and Maintenance of Internal Fire Hydrants and Hose Reels on Premises. Bureau of Indian Standards. Publisher.Internal hydrants, landing valves and hose reels.
  • IS 15105 (2002 (reaffirmed)) — IS 15105 — Design and Installation of Fixed Automatic Sprinkler Fire Extinguishing Systems — Code of Practice. Bureau of Indian Standards. Publisher.Sprinkler hazard classification, design density, head spacing and coverage, water supplies.
  • IS 2189 (2008) — IS 2189 — Selection, Installation and Maintenance of Automatic Fire Detection and Alarm System — Code of Practice. Bureau of Indian Standards. Publisher.Detector selection, zoning, installation and maintenance of fire alarm systems.
  • State Fire Service Acts and Rules — State Fire and Emergency Services Acts and Rules (state-specific). State governments. Fire NOC application, inspection, issue and renewal — the process and periodicity differ by state.

Standards are cited to support the technical statements on this page. Where a standard has been revised, the edition shown is the one verified at the time of review; the edition in force for a project is the one the authority applies.

Before you ask us to quote: the Fire Protection buyer's guide lists what to have ready, what drives cost and timeline, and the approvals that usually apply.

Approved makes

Makes we specify for Fire Detection & Alarm

Tier-1 manufacturers whose equipment we design around and install. The specification names the make; the site is held to it.

Honeywell Notifier Ravel Edwards Siemens

Need Fire Detection & Alarm for your project?

Get a free consultation and quote. We design, take all approvals, and execute — you stay stress-free.

ONE PARTNER. END TO END. You focus on your business — we handle the rest.
Quality Safety Commitment
Chat / Get Quote