Fire pump room contractor — main, diesel standby and jockey pumps in a code-compliant pump room

Main, standby (diesel) and jockey pump sets with controllers, sized for the hydrant + sprinkler demand, in a code-compliant pump room.

Enquire: Fire Pumps & Pump Room

Step 1 of 3

What do you need?
What kind of facility?
Roughly how big is the project?
Where should our engineer call you?

No forms to chase — an engineer calls you back. We never share your number.

In one paragraph

Fire Pumps & Pump Room by Secured Engineers Pvt. Ltd.

Secured Engineers Pvt. Ltd. — an ISO 9001:2015-certified MEPF and solar EPC contractor with offices in Ludhiana, Punjab and Noida (Delhi NCR) — provides Fire Pumps & Pump Room as part of its Fire Protection scope: Main, standby (diesel) and jockey pump sets with controllers, sized for the hydrant + sprinkler demand, in a code-compliant pump room. 535+ projects across 18+ Indian states.

Enquiries: +91 70099 87817 · sales@securedengineers.com · request a project proposal

Why it matters

What this system decides for your project

Pumps deliver the pressure and flow the whole system depends on. Listed, correctly sized pump sets are non-negotiable for Fire-NOC and reliable operation in an emergency.

You need a quote for this if: Every hydrant/sprinkler project — the heart of the firefighting system.

Scope

Scope of work

The pump sets are sized for the combined hydrant and sprinkler demand at the required pressure, with an electric main pump, a diesel standby of equal duty, and a jockey pump to hold the system pressurised. The pump room is designed to NBC — its location and access, the tank capacity and the suction arrangement (positive suction, or the priming the code allows), ventilation and exhaust for the diesel set, drainage, and the electrical supply and controllers with auto-start on pressure drop. We supply and install the pumps, engines, controllers, header, valves, the tank connections and the room's own services.

How it is delivered — and what you receive

Each pump is run against its curve — pressure and flow measured — and the auto-start sequence proven: the jockey holds pressure, the main starts on the first drop, the diesel starts if the main fails or on a further drop. The diesel set is run for the duration the standard requires, with its batteries, fuel and cooling checked. The test is witnessed by the fire officer for the NOC and repeated on the AMC schedule. The client receives the pump curves, the controller settings and the test log.

Sources and standards

  • NBC 2016 Part 4 (2016) — National Building Code of India 2016, Part 4 — Fire and Life Safety. Bureau of Indian Standards. Publisher.Occupancy classification, fire-protection systems required by building type and height, static water storage, pumps, exits, refuge, compartmentation, stair pressurisation.
  • IS 3844 (1989 (reaffirmed)) — IS 3844 — Code of Practice for Installation and Maintenance of Internal Fire Hydrants and Hose Reels on Premises. Bureau of Indian Standards. Publisher.Internal hydrants, landing valves and hose reels.
  • IS 15105 (2002 (reaffirmed)) — IS 15105 — Design and Installation of Fixed Automatic Sprinkler Fire Extinguishing Systems — Code of Practice. Bureau of Indian Standards. Publisher.Sprinkler hazard classification, design density, head spacing and coverage, water supplies.
  • IS 2189 (2008) — IS 2189 — Selection, Installation and Maintenance of Automatic Fire Detection and Alarm System — Code of Practice. Bureau of Indian Standards. Publisher.Detector selection, zoning, installation and maintenance of fire alarm systems.
  • State Fire Service Acts and Rules — State Fire and Emergency Services Acts and Rules (state-specific). State governments. Fire NOC application, inspection, issue and renewal — the process and periodicity differ by state.

Standards are cited to support the technical statements on this page. Where a standard has been revised, the edition shown is the one verified at the time of review; the edition in force for a project is the one the authority applies.

Before you ask us to quote: the Fire Protection buyer's guide lists what to have ready, what drives cost and timeline, and the approvals that usually apply.

Approved makes

Makes we specify for Fire Pumps & Pump Room

Tier-1 manufacturers whose equipment we design around and install. The specification names the make; the site is held to it.