Fire extinguisher supply, placement and AMC — ABC, CO₂, foam and K-class to IS 15683

ABC, CO₂, foam and K-class portable and trolley-mounted extinguishers, placed and refilled to code with signage and training.

Enquire: Fire Extinguishers & Portables

Step 1 of 3

What do you need?
What kind of facility?
Roughly how big is the project?
Where should our engineer call you?

No forms to chase — an engineer calls you back. We never share your number.

In one paragraph

Fire Extinguishers & Portables by Secured Engineers Pvt. Ltd.

Secured Engineers Pvt. Ltd. — an ISO 9001:2015-certified MEPF and solar EPC contractor with offices in Ludhiana, Punjab and Noida (Delhi NCR) — provides Fire Extinguishers & Portables as part of its Fire Protection scope: ABC, CO₂, foam and K-class portable and trolley-mounted extinguishers, placed and refilled to code with signage and training. 535+ projects across 18+ Indian states.

Enquiries: +91 70099 87817 · sales@securedengineers.com · request a project proposal

Why it matters

What this system decides for your project

Portables are the first line of defence for small fires and a basic statutory requirement. Correct type-placement matters — the wrong agent on the wrong fire makes it worse.

You need a quote for this if: Every premises — offices, kitchens, factories and warehouses.

Scope

Scope of work

Extinguisher type is matched to the fire class in each area — ABC for general spaces, CO₂ for electrical rooms, foam for flammable liquids, K-class for commercial kitchens — and the number and placement follow IS 2190 for the floor area and the travel distance to the nearest unit. We supply units to IS 15683, mount them with signage, prepare the placement plan the fire officer checks, and train the occupants who will use them.

How it is delivered — and what you receive

Each unit is tagged with its refill and pressure-test dates and recorded on a register that the AMC maintains — periodic visual checks, annual servicing and hydrostatic testing at the interval the standard sets — because the Fire NOC renewal asks for that register. Discharged units are refilled and returned, not left empty. The client receives the placement plan, the register and the training record.

Sources and standards

  • NBC 2016 Part 4 (2016) — National Building Code of India 2016, Part 4 — Fire and Life Safety. Bureau of Indian Standards. Publisher.Occupancy classification, fire-protection systems required by building type and height, static water storage, pumps, exits, refuge, compartmentation, stair pressurisation.
  • IS 3844 (1989 (reaffirmed)) — IS 3844 — Code of Practice for Installation and Maintenance of Internal Fire Hydrants and Hose Reels on Premises. Bureau of Indian Standards. Publisher.Internal hydrants, landing valves and hose reels.
  • IS 15105 (2002 (reaffirmed)) — IS 15105 — Design and Installation of Fixed Automatic Sprinkler Fire Extinguishing Systems — Code of Practice. Bureau of Indian Standards. Publisher.Sprinkler hazard classification, design density, head spacing and coverage, water supplies.
  • IS 2189 (2008) — IS 2189 — Selection, Installation and Maintenance of Automatic Fire Detection and Alarm System — Code of Practice. Bureau of Indian Standards. Publisher.Detector selection, zoning, installation and maintenance of fire alarm systems.
  • State Fire Service Acts and Rules — State Fire and Emergency Services Acts and Rules (state-specific). State governments. Fire NOC application, inspection, issue and renewal — the process and periodicity differ by state.

Standards are cited to support the technical statements on this page. Where a standard has been revised, the edition shown is the one verified at the time of review; the edition in force for a project is the one the authority applies.

Before you ask us to quote: the Fire Protection buyer's guide lists what to have ready, what drives cost and timeline, and the approvals that usually apply.

Approved makes

Makes we specify for Fire Extinguishers & Portables

Tier-1 manufacturers whose equipment we design around and install. The specification names the make; the site is held to it.

Ceasefire Agni Safex Kanex Omex

Need Fire Extinguishers & Portables for your project?

Get a free consultation and quote. We design, take all approvals, and execute — you stay stress-free.