VAV (Variable Air Volume)

VAV — variable air volume — conditions zones by modulating how much air each zone box admits, rather than reheating constant air; the central fan then slows to match total demand, cutting fan energy while every zone holds its own setpoint.

Why it matters on an MEPF project

Constant-volume systems ride one airflow all day and fight diversity with reheat or overcooling; VAV lets a west-facing meeting room and a shaded corridor each take what they need. Because fan power falls steeply as flow reduces, VAV's part-load economics is where it earns its complexity — offices with variable occupancy are its home ground.

It succeeds or fails on controls discipline: box calibration, duct static-pressure reset logic, and minimum-flow settings that keep ventilation honest at low load. A VAV system with untuned minimums quietly becomes a constant-volume system wearing dampers.

How it's specified in practice

VAV essentials — VAV (Variable Air Volume)
ParameterTypical / working positionGoverning reference
Zone deviceVAV box with damper (+ optional reheat) per zonesystem design
Fan controlVFD on supply fan tracking duct static setpointcontrols design
Minimum flowSet to preserve fresh-air ventilation at low loadsventilation basis (NBC Part 8)
Payback driverFan-energy reduction at part load + zone comfortECBC-era practice

Common mistakes

  • Zones drawn by geometry rather than load similarity.
  • Static setpoint fixed high forever — the VFD never actually saves.
  • Minimum flows set to zero, starving ventilation in mild weather.
  • Commissioned once, never re-balanced after fit-out churn.

Related on this site

Frequently asked

Is VAV worth it for a small office?

Below a certain scale the controls overhead outweighs the fan savings — simpler zoning or VRF often fits better. Diverse mid-to-large floor plates are where VAV pays.

Why is one VAV zone always hot?

Usually an under-flowing box: mis-calibrated, damper stuck, or the static reset starving the index run. Trend the box data — VAV systems tell on themselves if anyone reads them.

Standards referenced: NBC 2016 Part 8 (ventilation basis) · ECBC 2017