Solar inverter supply and installation — string and central inverters with monitoring and grid protection
String and central inverters with MPPT optimisation, monitoring and grid-protection, sized to the array and DISCOM requirements.
Enquire: Inverters (String / Central)
Step 1 of 3
Your request is in
One of our engineers will call you shortly.
Inverters (String / Central) by Secured Engineers Pvt. Ltd.
Secured Engineers Pvt. Ltd. — an ISO 9001:2015-certified MEPF and solar EPC contractor with offices in Ludhiana, Punjab and Noida (Delhi NCR) — provides Inverters (String / Central) as part of its Solar EPC scope: String and central inverters with MPPT optimisation, monitoring and grid-protection, sized to the array and DISCOM requirements. 535+ projects across 18+ Indian states.
Enquiries: +91 70099 87817 · sales@securedengineers.com · request a project proposal
What this system decides for your project
The inverter sets real-world efficiency and grid compliance. A reliable, well-matched inverter with monitoring maximises export and flags faults before they cost generation.
You need a quote for this if: Every grid-tied or hybrid solar plant.
Scope of work
Inverter selection follows the array design — string inverters where roofs have several orientations or shading patterns and per-string MPPT protects yield, central inverters where a large uniform array makes them economical — with the DC/AC ratio, the MPPT voltage window and the grid-protection settings the DISCOM's connection standard requires. Monitoring is specified so generation, faults and string performance are visible remotely. We supply and install the inverters, DC combiner boxes, AC distribution and the monitoring hardware.
How it is delivered — and what you receive
Inverters are commissioned with the protection settings — voltage and frequency limits, anti-islanding — configured to the DISCOM's requirements and recorded, because these are checked at the net-metering inspection. Monitoring is verified against the meter, and the client's team is shown the portal. The client receives the settings record, the commissioning report and the monitoring access.
Sources and standards
- MNRE ALMM — Approved List of Models and Manufacturers (ALMM) for solar PV modules. Ministry of New and Renewable Energy. Publisher.Which module models and manufacturers are eligible for government-linked and subsidised solar projects.
- IEC 61215 / IEC 61730 — IEC 61215 (design qualification) and IEC 61730 (safety qualification) — photovoltaic modules. International Electrotechnical Commission. Publisher.Module qualification and safety testing.
- IEC 62109 — IEC 62109 — Safety of power converters for use in photovoltaic power systems. International Electrotechnical Commission. Publisher.Inverter safety.
- CEA (Measures relating to Safety and Electric Supply) Regulations (2023 (superseding the 2010 regulations)) — Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations. Central Electricity Authority. Publisher.Safety requirements for electrical installations, inspection of HT installations before energisation, periodic inspection, earthing and protection.
Standards are cited to support the technical statements on this page. Where a standard has been revised, the edition shown is the one verified at the time of review; the edition in force for a project is the one the authority applies.
Before you ask us to quote: the Solar EPC buyer's guide lists what to have ready, what drives cost and timeline, and the approvals that usually apply.
Makes we specify for Inverters (String / Central)
Tier-1 manufacturers whose equipment we design around and install. The specification names the make; the site is held to it.
Related to Inverters (String / Central)
The terms behind it
Run the numbers
Read before you specify
Need Inverters (String / Central) for your project?
Get a free consultation and quote. We design, take all approvals, and execute — you stay stress-free.